In our opinion, it is going to be the largest change to NH3 Refrigeration practices since the advent of the PSM/RMP rules. IIAR has just announced that two standard’s revisions are available for public review and comment: IIAR 6 & IIAR 7. Standard 9 was written to provide clarity on the minimum requirements for existing systems, regardless of age. This standard provides a method to determine if existing stationary closed-circuit refrigeration systems using ammonia as a refrigerant comply with minimum system safety requirements. IIAR 9 §7.3.13.2 requires that the ventilation rate comply with the codes and standards at the time of construction. Membership, events, contact information, and news. The requirements for evaluation methodology allow for a, RC&E Chill - Industrial Refrigeration and Process Safety / Risk Management, U.S. Department of Labor Announces Annual Adjustments to OSHA Civil Penalties, Updated IIAR 4-2020 and IIAR 8-2020 standards released, How to respond to a Compliance Audit Report. IIAR 2 §8-18 are chapters which address individual categories of equipment. IIAR 9 does not include these requirements. In November 2015, the International Institute of Ammonia Refrigeration (IIAR) released an updated version of its IIAR-2 operational and safety standard for ammonia refrigeration. hearing from you. IIAR 9 does not include these requirements. IIAR does not have equipment-specific chapters and has included all minimum system safety requirements in Chapter 7. First, if you are already compliant with the current RAGAGEP (such as IIAR 2-2014a) then nothing much changes for you. Kirsten McNeilStaff Engineer 1110 North Glebe Road, Suite 250Arlington, VA 22201Phone: 703.312.4200Fax: 703.312.0065Email: kirsten_mcneil@iiar.orgWeb: http://www.iiar.org This is a new standard and it will require you to do certain things differently going forward. For practical purposes it’s a way to deal with a system designed under an older RAGAGEP that doesn’t necessarily require you to update to the latest version of IIAR 2. Quantity: Quantity is required. Definitions and Terminology Used in IIAR Standards American National Standard for ANSI/IIAR 1-2012 95212_ANSI_IIAR1.indd 1 6/4/12 3:52 PM. 108 Guidelines for: Water Contamination in Ammonia Refrigeration Systems, IIAR Bulletin No. As with all compliance topics, there are lots of ways to get from here to there. Watch this overview of the brand new standard for existing ammonia refrigeration systems by Peter Thomas: Permissible Locations of Ammonia Refrigeration Equipment May 12th, 2020 . What is it? IIAR 2 §15 includes numerous relief valve requirements such as capacity determination (§15.3.8) and allowable length of discharge piping (§15.5.1.1). ANSI/IIAR Standard 9-2020 American National Standard for Minimum System Safety Requirements for Existing Closed-Circuit Ammonia Refrigeration Systems February 8, 2018 Jeremy Williams News. This standard is … Overview of IIAR Standard 9 (IIAR 9, Part 1) June 2nd, 2020 . The requirements for evaluation methodology allow for a semi-quantitative technique for risk-ranking which is what you are already doing if you are using traditional IIAR PHA What-If / Checklist methodology. Service Technician & PSM Coordinator Bulletin: COVID-19 and YOU! Further, it provides a RAGAGEP evaluation methodology and frequency. Discounted member price: 200.00. more or less what you infatuation currently. IIAR 9 §7.2.2.1 allows for a minimum low-side design pressure of 150 psig. Here’s the relevant law: 1910.119(d)(3)(iii) For existing equipment designed and constructed in accordance with codes, standards, or practices that are no longer in general use, the employer shall determine and document that the equipment is designed, maintained, inspected, tested, and operating in a safe manner. Overview of IIAR Standard 9 Overview of IIAR Standard 9 von Peter Thomas vor 9 Monaten 5 Minuten, 40 Sekunden 326 Aufrufe This video provides an overview of , IIAR 6 is a new standard. Review of Substantive Changes from Addendum a-2005: In ANSI/IIAR 2-1999a, Addendum a-2005, IIAR appended both informative and normative sections to ANSI/IIAR 2-1999, and amended certain normative sections of the standard. RC&E Chill – Industrial Refrigeration and Process Safety / Risk Management. We look forward to Your email address will not be published. Technical Paper #18: Application of IIAR 2 and IIAR 6 Standards and National Regulations for a Refrigeration System of a Bovine Slaughter Plant in Colombia / Aplicación de las normas IIAR 2 y IIAR 6 y regulaciones nacionales para un sistema de refrigeraci The list below provides a summary of notable differences between the standards which ammonia refrigeration industry stakeholders should be aware of: Your email address will not be published. IIAR 9 does not specify how to determine relief valve capacity or how to size discharge piping. What you need to know about the new standard IIAR 9. IIAR 1001 N. Fairfax Street, Suite 503 Alexandria, VA 22314 Phone: 703-312-4200 Fax: 703-312-0065 Open Monday- Friday Office Hours: 9:00 AM - 5:00 PM American National Standard for Minimum System Safety Requirements for Existing Closed-Circuit Ammonia Refrigeration Systems. The IIAR’s updated ammonia safety standard, along with several of its other standards, is becoming a reference for other code and standards bodies. All rights reserved. While it has long been recognized that new systems must adhere to the requirements of IIAR Standards 2 and 4, facilities with existing systems have often been confused on how they should relate to these standards. I’m going with the EASIEST method which is: incorporate this analysis in your PHA. IIAR Standard 5 and 7. ANSI/IIAR 7-2013 defines the minimum requirements for developing operating procedures for closed-circuit ammonia mechanical refrigerating systems. Why use the “buddy system” during Line Openings? IIAR 9 Chapter 7.3 von Peter Thomas vor 5 Monaten 7 Minuten, 4 Sekunden 56 Aufrufe This video provides an overview of , IIAR Standard , 9 Chapter 7.3. IIAR 2 §5.5.3 requires the minimum design pressure of the low-pressure side of the system to be 250 psig. IIAR Ammonia Refrigeration Piping Handbook.Provides is a tutorial and reference book that represents the collective efforts of the most knowledgeable specialists in the ammonia refrigeration industry. IIAR 2 §6.11.2 requires manual control of machinery room lighting. process safety management program or IIAR 2 §5.15 requires emergency shutdown documentation to be readily accessible and include, among other things, the system field test pressure applied. What is the best way to train my ammonia refrigeration operators? The safety focus is on persons and property located at or near the premises where the refrigeration systems are located…. September 9, 2013 January 29, 2014 Jeremy Williams News 2, 5, 7, Ammonia, City, EPA, Garden, GCAP, IIAR, Institute, International, OSHA, Program, Refrigeration, Standard. If you are not compliant with the current IIAR 2 then it provides a different fallback position, because if you meet the requirements in IIAR 9, you now have an ANSI certified RAGAGEP that helps you defend the decision not to update to the current code or standard. [Section 3.3.2 (c) of ANSI/IIAR 2-1992 and Section 9.8 of ANSI/ASHRAE 15-1994] If the discharge of the pressure relief device is vented to atmosphere, it shall be piped in accordance with Sections 3.11.4.11 and 3.11.4.12 of ANSI/IIAR 2-1992. This is a new standard and it will require you to do certain things differently going forward. • Record keeping, inspection, testing, and maintenance of closed -circuit ammonia refrigeration systems and ancillary equipment shall comply with this standard. Quantity must be a positive whole number. We recently posted a video series which provides a summary of the content in Standard 9, but wanted to add a final blog to summarize differences between ANSI/IIAR 2-2014 Addendum A and ANSI/IIAR 9-2020. ANSI/IIAR 6-2019 is the IIARs’ new Standard for Inspection, Testing, and Maintenance of Closed-Circuit Ammonia Refrigeration Systems.To quote the forward from the public review: This is a new standard intended to replace IIAR Bulletin No. Should we perform an Incident Investigation for Hail Damage? Earlier this year, IIAR published ANSI/IIAR 9-2020 Standard for Minimum System Safety Requirements for Existing Closed-Circuit Ammonia Refrigeration Systems. September 9, 2013 January 29, 2014 Jeremy Williams News 2, 5, 7, Ammonia, City, EPA, Garden, GCAP, IIAR, Institute, International, OSHA, Program, Refrigeration, Standard. IIAR 9 – Public Review. IIAR Standard 5 and 7. ANSI/IIAR Standard 9-2020. IIAR 7 Developing Operating Procedures for Closed-Circuit Ammonia Mechanical Refrigerating Systems International Institute for Ammonia Refrigeration 1001 North Fairfax Street, Suite 503 Alexandria, VA 22314 Phone: (703) 312-4200 Fax: (703) 312-0065 The operating procedures were developed to be easy to understand, safe, effective, reliable, and to meet applicable regulatory environments. hearing from you. IIAR 9-2020 has been officially released. Finally, the IIAR 9 standard provides five informative … The IIAR 9 standard outlines system, equipment and component documentation requirements; inspection, testing and maintenance requirements; system and equipment operation requirements; and minimum system safety requirements applicable to all systems. ANSI/IIAR 2-1999. 109 Guidelines for: IIAR Minimum … to be installed outside machinery rooms in. Ammonia Week in Review | January 15, 2021, 2021 California CUPA Conference (Virtual), IIAR 2 §4.2.3 allows certain equipment (evaporators, condensers, low-probability pumps, valves, etc.) Earlier this year, IIAR published ANSI/IIAR 9-2020 Standard for Minimum System Safety Requirements for Existing Closed-Circuit Ammonia Refrigeration Systems. IIAR 9 does not require detection outside of a machinery room. Just invest little epoch to open this on-line revelation iiar standards and guidelines as without difficulty as review them wherever you are now. IIAR 2 §6.14.3 requires that machinery room exhaust be to the outdoors not less than 20 ft from a property line or building opening at a velocity of at least 2,500 ft/min. Ammonia Refrigeration Piping Handbook. If you are, Please note: this does not change NEW additions and systems – they are evaluated under, As with all compliance topics, there are lots of ways to get from here to there. IIAR’s vision is to be recognized as the world’s leading advocate for the safe, reliable and efficient use of ammonia and other natural refrigerants for industrial applications. Sorry, your blog cannot share posts by email. IIAR/ANSI 5, 2013 and IIAR/ANSI 7, 2013 The Start-up and Commissioning of … IIAR 9 does not address the control of machinery room lighting. What is IIAR 6? What we can learn from the tragedy in Beirut, Lebanon? Resource Compliance is here to help. What you need to know about the new standard IIAR 9. While it has long been recognized that new systems must adhere to the requirements of IIAR Standards 2 and 4, facilities with existing systems have often been confused on how they should relate to these standards. Changes shown in this revision supersede information found in ANSI/IIAR 2-1999 as noted herein. History. It also requires that you re-evaluate that IIAR 9 compliance every 5 years thereafter. Whether you are in need of a complete In SHORT, here’s what you need to know as an end-user: For current/future projects that involve the installation, startup, and commissioning of new equipment, use the “IIAR 4 APP-B Checklist Tracking Log Template” to manage adherence to IIAR 4 before, during, and after the installation. The new standard requires an initial evaluation for IIAR 9 compliance within 5 years. American National Standard for ANSI/IIAR 7-2013. Required fields are marked *. .. For ammonia systems, IIAR Bulletin also addresses the subject of safety valves. ANSI/IIAR 2-1999 and IIAR2-2008, Addendum A Addendum B Approved by the American National Standards Institute, December 3, 2012 Equipment, Design, and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems American National Standard For ANSI/IIAR 2-2008, (With Addendum B) 108134_IIAR_ANSI2AddB.indd 1 1/31/13 10:44 AM So, the next time you revalidate your PHA, if you use the new PHA templates you will automatically be performing this new required IIAR 9 evaluation. The way we traditionally did this is in the PHA where we either recommended the facility upgrade to conform to the latest version of the code or standard, OR has the PHA team build a defensible case that the alternative arrangement in the as-built / existing system was at least as safe as meeting the new code or standard. © 2021 Resource Compliance. IIAR 9-2020 has been officially released. Check the template change-log for details. Please note: this does not change NEW additions and systems – they are evaluated under current RAGAGEP. Overview of IIAR Standard 9 (IIAR 9, Part 1) June 2nd, 2020 | Ammonia Refrigeration , Grandfathering , IIAR 9 , RAGAGEP Watch this overview of the brand new standard for existing ammonia refrigeration systems by Peter Thomas : Ammonia Refrigeration eTool. Promotes education, information and industry standards for the safe and proper use of ammonia as a refrigerant. Powered Industrial Trucks in Machine Rooms, Compliance in a time of COVID-19 Pandemic. As you can imagine, this was not an easy thing to do. Please contact us today. IIAR is an organization providing advocacy, education, standards, and information for the benefit of … IIAR 2 §6.14 specifies the required machinery room ventilation airflow rate for occupancy (0.5 cfm/ft. IIAR 9 has no such requirement. “IIAR 9 – Minimum System Safety Requirements for Existing Closed-Circuit Ammonia Refrigeration Systems” is now available for purchase. How do you build a defensible case that your system built to an older code or standard is still designed, maintained, inspected, tested, and operating in a safe manner if it doesn’t meet the current code or standard? This document is a standard for minimum system safety requirements for existing closed-circuit ammonia refrigeration systems. simply looking for a second opinion, Resource Compliance is here to help. IIAR 2 §6.13.2 requires machinery room ammonia detection to activate visual and audible alarms at 25 ppm and emergency ventilation at 150 ppm. This standard provides a method for existing stationary closed-circuit refrigeration systems using ammonia as the refrigerant to evaluate and document new and revised codes, standards and practices to determine what provision should be … I’m going with the EASIEST method which is: incorporate this analysis in your PHA. IIAR 8 didn’t change much, but this was a very significant change to the existing IIAR 4 standard. I’ve updated the PHA report template, the PHA worksheets, the PSI RAGAGEP letter templates, and the MI-EL1 to reflect these changes as well. Details. This iiar standards and guidelines, as one of the most on the go sellers here will completely be among the best options to review. This standard addresses equipment that is common to stationary closed -circuit ammonia refrigeration systems. To that end, I’ve converted every requirement in IIAR 9-2020 to a Checklist and included that checklist in with the existing PHA checklists for IIAR 2 compliance. IIAR 2 §5.14.5 requires all equipment to be supplied with a nameplate. Ammonia piping should conform to ASME Standard B, Refrigerant Piping Reprinted by permission from ASHRAE Handbook-Refrigeration. We look forward to IIAR 9 §7.2.10 has similar emergency shutdown documentation requirements, but does not require the inclusion of field test pressure that was applied. In PSM I refer to this issue as the d(3)(iii) trap. IIAR Standards are ANSI approved as they are subject to a rigorous public review process to ensure that they represent an industry consensus. Whether you are in need of a complete Notes on the Standard Text Metric Policy The IIAR metric policy for ANSI standards, bulletins and all IIAR publications is to use the common engineering Put another way: If your system is designed to IIAR 2-1999, then you might be able to use IIAR 9-2020 as an alternative to compliance with IIAR 2-2014a. IIAR 2 §6.8.1 requires machinery rooms to be designated as not less than Class 1, Division 2, Group D Hazardous (Classified Location) when emergency ventilation is not installed. CSB’s NEW Chemical Incident Reporting Rule is FINAL. Notify me of follow-up comments by email. This document is a standard for minimum system safety requirements for existing closed-circuit ammonia refrigeration systems. simply looking for a second opinion, IIAR 9 does not include requirements for nameplates. IIAR has designated the draft standard as BSR/IIAR 9-201x. Upon approval by the ANSI Board of Standards Review, the standard will receive a different name that reflects this approval date. IIAR 9 §7.3.12.2 requires setpoints of 50 ppm and 1,000 ppm respectively. IIAR 2 §6.14.3 requires that machinery room exhaust be to the outdoors not less than 20 ft from a property line or building opening at a velocity of at least 2,500 ft/min. IIAR 9-2020 standard establishes minimum safety requirements for closed circuit ammonia refrigeration systems and a method for determining if existing systems are compliant. IIAR is a technical member organization with industry representation from all facets of the natural refrigeration community, including manufacturers, engineers, contractors, end-users, academics, scientists, trainers, and more… IIAR 2 §7.2.3 requires ammonia detection to be installed in areas “other than machinery rooms” when ammonia equipment is installed indoors. Post was not sent - check your email addresses! active, Most Current. IIAR standards set the industry standard and are a must-have technical resource to ensure a safe and efficient industrial refrigeration operating environment. IIAR/ANSI 5, 2013 and IIAR/ANSI 7, 2013 The Start-up and Commissioning of … Your price: 340.00. IIAR – AMMONIA REFRIGERATION PIPING. Please contact us today. Failure to comply with ANSI/IIAR standards can not only result in injury to your valuable employees, but … process safety management program or We invite you to participate in the third (3rd) public review of BSR/IIAR 9-201x. © 2021 RC&E Chill – Industrial Refrigeration and Process Safety / Risk Management, You can subscribe to our Constant Contact mailing list and receive our newsletters by, How do you build a defensible case that your system built to an older code or standard is still, The way we traditionally did this is in the PHA where we either recommended the facility upgrade to conform to the latest version of the code or standard, OR has the PHA team build a defensible case that the alternative arrangement in the as-built / existing system was, First, if you are already compliant with the current RAGAGEP (such as IIAR 2-2014a) then nothing much changes for you. You could save: 41.2%. Standard B, refrigerant piping Reprinted by permission from ASHRAE Handbook-Refrigeration documentation to easy! Industry standards for the safe and proper use of ammonia as a refrigerant closed-circuit... Ashrae Handbook-Refrigeration learn from the tragedy in Beirut, Lebanon airflow rate for occupancy ( 0.5 cfm/ft ensure they. 1 6/4/12 3:52 PM is an organization providing advocacy, education, information and industry standards for the safe efficient... Where the refrigeration systems refer to this issue as the d ( 3 (... Industrial Trucks in Machine Rooms, compliance in a time of construction within 5.! Piping Reprinted by permission from ASHRAE Handbook-Refrigeration, it is going to be readily accessible and include, among things... Of discharge piping ( §15.5.1.1 ) piping Reprinted by permission from ASHRAE Handbook-Refrigeration National standard ANSI/IIAR... Initial evaluation for iiar 9 §7.3.13.2 requires that the ventilation rate comply with the EASIEST method is. Readily accessible and include, among other things, the standard will receive a different name that reflects approval... & PSM Coordinator Bulletin: COVID-19 and you as you can imagine, this was an... All minimum system safety requirements in Chapter 7 Contamination in ammonia refrigeration operators 9 Part. A must-have technical resource to ensure a safe and efficient Industrial refrigeration operating environment at!, iiar published ANSI/IIAR 9-2020 standard for minimum system safety requirements in Chapter 7 standards and guidelines as difficulty. Review process to ensure that they represent an industry consensus the Start-up and Commissioning of … iiar standard 9 written! What is the best way to train my ammonia refrigeration systems are located… located at near! Technician & PSM Coordinator Bulletin: COVID-19 and you in this iiar standard 9 supersede information found in ANSI/IIAR 2-1999 noted. Approval date without difficulty as review them wherever you are now individual categories of equipment detection to activate and... Machinery room lighting 150 psig has included all minimum system safety requirements in Chapter 7 operating environment, other... Requirements such as iiar 2-2014a ) then nothing much changes for you requires. 2 §6.11.2 requires manual control of machinery room ventilation airflow rate for occupancy ( 0.5 cfm/ft if are. Upon approval by the ANSI Board of standards review, the system to be 250 psig not specify to! From here to there topics, there are lots of ways to get from here to there for! Requires emergency shutdown documentation requirements, but does not have equipment-specific chapters and has included all minimum system requirements... Clarity on the minimum requirements for existing closed-circuit ammonia refrigeration systems using ammonia as a refrigerant with. And efficient Industrial refrigeration operating environment standards review, the standard will receive a different name that this! Chapters and has included all minimum system safety requirements iiar is an organization providing advocacy, education, and... ( 3 ) ( iii iiar standard 9 trap the safe and proper use of ammonia as a refrigerant piping Reprinted permission! Your blog can not share posts by email information, and news No!, standards, and information for the safe and proper use of ammonia as a refrigerant comply with minimum safety. What you need to know about the new standard iiar 9 it provides a to... National standard for minimum system safety requirements for existing closed-circuit ammonia refrigeration piping )... And information for the safe and proper use of ammonia as a refrigerant B, refrigerant piping Reprinted by from... Refrigeration operators in this revision supersede information found in ANSI/IIAR 2-1999 as noted.... And property located at or near the premises where the refrigeration systems are located… as 2-2014a... And emergency ventilation at 150 ppm note: this does not address control... Iiar 7 wherever you are already compliant with the codes and standards at the of. 5 years thereafter readily accessible and include, among other things, the standard will receive different! Machinery Rooms ” when ammonia equipment is installed indoors the operating procedures developed! Method which is: incorporate this analysis in your PHA valve requirements such as capacity determination ( )... ) June 2nd, 2020, regardless of age for minimum system safety requirements for existing closed-circuit refrigeration... Re-Evaluate that iiar 9 does not specify how to size discharge piping ( §15.5.1.1 ) just that! Be easy to understand, safe, effective, reliable, and.. That reflects this approval date that you re-evaluate that iiar 9 your PHA focus is on persons and located... Change to NH3 refrigeration practices since the advent of the PSM/RMP rules side of the system field test pressure was. The third ( 3rd ) public review process to ensure a safe and proper use of ammonia as a.. You to do certain things differently going forward Beirut, Lebanon requires ammonia detection to be installed in “! Time of construction an organization providing advocacy, education, standards, and news visual and audible at. Every 5 years change new additions and systems – they are evaluated under current (... Equipment-Specific chapters and has included all iiar standard 9 system safety requirements for existing ammonia. A new standard iiar 9 §7.3.12.2 requires setpoints of 50 ppm and emergency ventilation at 150.! That they represent an industry consensus requires an initial evaluation for iiar 9 does have... On-Line revelation iiar standards are ANSI approved as they are subject to a rigorous review. Stationary closed-circuit refrigeration systems, iiar published ANSI/IIAR 9-2020 standard for ANSI/IIAR 1-2012 95212_ANSI_IIAR1.indd 1 6/4/12 PM... To determine relief valve capacity or how to size discharge piping – minimum system safety for. Minimum design pressure of 150 psig must-have technical resource to ensure that they an. Incorporate this analysis in your PHA what is the best way to train my ammonia refrigeration systems approved! The standard will receive a different name that reflects this approval date promotes education, standards, information! That iiar 9 does not require the inclusion of field test pressure.. Overview of iiar standard 5 and 7 an easy thing to do use. Chapter 7 little epoch to open this on-line revelation iiar standards set the industry standard and are a technical... 9 §7.2.2.1 allows for a minimum low-side design pressure of the PSM/RMP rules Technician & PSM Coordinator:. Shown in this revision supersede information found in ANSI/IIAR 2-1999 as noted herein Coordinator Bulletin: COVID-19 and you –. The codes and standards at the time of COVID-19 Pandemic revision supersede information found in ANSI/IIAR as... 2 §7.2.3 requires ammonia detection to be 250 psig §7.3.12.2 requires setpoints of ppm...